HY1360 Ground on-resistance meter verification device is a professional used to verify and verify the ground resistance meter (also known as the ground resistance tester) equipment. The following is a detailed introduction to the verification device:
I. Main use
HY1360 ground on-resistance meter verification device is mainly used to calibrate and verify the ground resistance meter to ensure the accuracy and reliability of its measurement results. The device is suitable for the safety inspection of power systems, electronic equipment and industrial equipment, as well as fault detection and performance evaluation of grounding systems.
Two, working principle
The working principle of the verification device is based on Ohm's law, that is, resistance is equal to voltage divided by current. By injecting a known current into the ground resistance meter and measuring the resulting voltage difference, the resistance value of the ground resistance can be calculated. By comparing the calculated value with the actual measured value of the ground resistance meter, the accuracy and precision of the ground resistance meter can be evaluated.
3. Main featuresHigh precision: The HY1360 ground on-resistance meter verification device has high precision, which can ensure the accurate calibration and verification of the ground resistance meter.
Multi-function: The device can not only be used to verify the ground resistance meter, but also can be used to measure and verify other related electrical parameters.
Easy to operate: The device is designed with intuitive user interface and operation flow, which makes the verification work more simple and fast.
Safe and reliable: The device is fully considered in the design and manufacturing process of safety factors to ensure that it will not cause harm to personnel and equipment in the verification process.
Four, the use of
When using the HY1360 ground on-resistance meter verification device, follow the following steps:
Preparation stage: Ensure that the ground resistance meter to be checked is in normal working condition, and connect the test cable required for the verification device.
Set parameters: According to the verification requirements, set the corresponding test parameters on the device, such as current value, test time, etc.
Start calibration: start the calibration device and start calibration of the ground resistance meter. During the verification process, observe and record the test results.
Result analysis: Compare the test results with the standard values to evaluate the accuracy and accuracy of the ground resistance meter.
Five, precautions
Before using the HY1360 ground on-resistance meter to verify the device, please read its instruction manual carefully to understand the operation methods and precautions of the device.
During the verification process, please ensure the safety of personnel and equipment to avoid electric shock or other safety accidents.
Regular maintenance and maintenance of the verification device to ensure its long-term stable operation.
In summary, the HY1360 ground on-resistance meter verification device is a high-precision, multi-functional, easy to operate and safe and reliable equipment, which is widely used in the safety inspection of power systems, electronic equipment and industrial equipment, as well as the fault detection and performance evaluation of grounding systems.